top of page
  • Nick

AI takes on... DeviceNet

ChatGPT takes on a protocol that I hope you never encounter: DeviceNet. If you are unaware of DeviceNet, enjoy this quick glimpse into one of my least favorite protocols.


Q: Can you write me a professional summary of the DeviceNet protocol, as applied to industrial control systems? Make sure to include advantages and limitations of the system, common issues with installations and a discussion about troubleshooting.


A: DeviceNet is a widely used communication protocol in industrial control systems that enables data exchange and control between devices and sensors. It offers several advantages for industrial automation but also has limitations and potential installation challenges that should be considered. Employing effective troubleshooting techniques is crucial to ensure reliable and efficient operations.


Advantages of DeviceNet:

1. Plug-and-Play Connectivity: DeviceNet provides a plug-and-play connectivity solution, allowing for easy integration of devices from different manufacturers, simplifying installation and reducing setup time. This is not completely untrue. Rockwell Automation did open this up, I simply argue that it does not make for easy integration.

2. Simplified Wiring: DeviceNet utilizes a bus topology, enabling devices to be connected on a single cable, resulting in reduced wiring complexity, lower costs, and easier maintenance. DeviceNet is just an application layer protocol sitting on top of CANBUS.

3. Scalability and Flexibility: DeviceNet supports a scalable architecture, allowing for the addition or removal of devices without disrupting the network. It also offers flexibility in terms of device placement and location, accommodating various industrial environments. While DeviceNet does allow some flexibility in making subnets, I see no technical benefit to using it over subnets in Ethernet/IP.

4. Cost-Effective Solution: DeviceNet's simplified wiring and ease of integration contribute to lower overall installation and maintenance costs, making it an attractive option for industrial control systems.

5. Diagnostics and Troubleshooting: DeviceNet supports diagnostics and troubleshooting capabilities, facilitating quick identification and resolution of network issues and device faults, minimizing downtime.


Limitations and Common Issues:

1. Limited Bandwidth: DeviceNet operates at lower bandwidths compared to some other protocols, which may restrict its suitability for applications that require high-speed data transfer or extensive amounts of data exchange.

2. Cable Length and Device Count: DeviceNet has limitations on cable length and the number of devices that can be connected on a single network, necessitating careful planning and consideration of network topology for larger installations.

3. Interoperability: While DeviceNet offers compatibility between devices from different vendors, occasional interoperability issues may arise due to variations in device profiles and compatibility. The some of only equipment my current employer gave up troubleshooting on was a DeviceNet vibration monitoring system on three large pumps. Compatibility testing is important to ensure seamless integration.

4. Addressing and Configuration: DeviceNet utilizes node addresses, and improper addressing or configuration of devices can result in communication errors or network conflicts. Attention to detail during device setup is crucial.

5. Electromagnetic Interference: DeviceNet installations may be susceptible to electromagnetic interference (EMI) due to the use of unshielded cables. Proper grounding and shielding techniques should be employed to minimize the impact of EMI.


Troubleshooting DeviceNet Systems:

1. Network Analysis: Conduct a thorough network analysis using specialized tools to identify network faults, such as cable issues, incorrect terminations, or device configuration errors, and take appropriate corrective measures.

2. Node Diagnostics: Utilize the diagnostics features available in DeviceNet devices to identify and resolve communication errors, faulty modules, or parameterization issues that may affect system performance.

3. Power and Grounding: Verify proper power supply and grounding for all devices, ensuring stable voltage levels and minimizing potential electrical noise.

4. Device Replacement and Firmware Updates: If a device is identified as faulty, consider replacing it with a compatible unit. Additionally, keep firmware versions up to date to ensure compatibility and take advantage of any performance improvements or bug fixes.

5. Vendor Support and Documentation: Leverage vendor support and documentation for troubleshooting guidance, particularly for complex issues or challenges in DeviceNet systems. Vendors can provide valuable expertise and resources.


In conclusion, DeviceNet is a widely utilized communication protocol in industrial control systems due to its plug-and-play connectivity, simplified wiring, scalability, and cost-effectiveness. While it offers numerous advantages, attention should be given to its limitations, such as limited bandwidth, cable length, and device count. Additionally, troubleshooting DeviceNet systems involves network analysis, node diagnostics, attention to power and grounding, device replacement, and collaboration with vendors. Implementing these troubleshooting techniques ensures smooth operations and helps maintain reliable communication in DeviceNet-based industrial control systems.


Overall: ChatGPT is less biased against DeviceNet than I am. Given my personal feelings on the matter, I see no way to write an impartial grade for ChatGPT. However, there are some significant details that are missing.


DeviceNet is still used by some legacy systems, in conjunction with more recent PLCs. CompactLogix and ControlLogix scanner cards exist to allow such older gear to be interfaced and continue use. In the event you are stuck servicing such equipment, you should be able to see it in RSLinx.


Baud rates are limited to 500 kb/s maximum, with run distance based off speed and cable size. There are three cable types. (Note: I know of no fiber that will work for this. Quite disappointing... but not a problem for ControlNet, let alone EthernetIP!)


Device numbering is "limited" to 0-63. 0 is the primary scanner. If you have multiple scanners (aka mutliple PLCs reading the same end device), put the others as low numbers. Keep the maximum number for your gear at 61. Your computer will be "62." Anything out of the box will default to 63.


I can see keeping DeviceNet to run legacy gear. If you have the option to take it out, I strongly suggest that you do so, as soon as possible!

6 views0 comments

Recent Posts

See All

Pro tips: Process Engineers

Pro tips exist to help you in your career. They usually focus on topics that I have experience with, but I had the pleasure of talking...

Podcasts on automation

It turns out there are good number of relevant podcasts for this field. They are also great for when you are on the road! Just a few...